[pdf] 
1-1 Scope of Application This document covers procedures and methods of tests, examinations and inspections to be performed to the Screw Compressor which has been manufactured and supplied by screw compressor vendors. 1-2 Purpose of Examination and lnspection The purpose of the examinations. .
2-1Genaeral General descriptionon examinations/inspections to be performed on the compressor proper and the relatedparts are mentioned in this chapter. The inspection itemsof each major part are shown in inspection and test plan. 2-2Material Inspection. .
After completion of the test, the rotors and the rotor chamber will be visually inspected through the discharge nozzle. (The discharge side is under most severe conditions, and the visual inspection of the discharge side is a normal practice to check a rotor. .
Following Items are measured in Heat Run, Mechanical Run and Performance Test: 1. Atmospheric Pressure 2. Atmospheric Temperature 3. Relative Humidity (Only in Performance Test) 4. Inlet Pressure 5. Inlet Temperature 6. Discharge Pressure. .
Following componenets are used for test from Shop Facilities: 1. Driver( Motor) 2. Couplings 3. Baseplate 4. Suction Filter 5. Suction Silencer 6. Discharge Silencer 7. Lube Seal Oail Unit (Include Oil Reservoir) 8. Piping 9. Instruments 10. Thrust Bearing T em perature.
[pdf] Key tasks include changing oil and filters, cleaning air filters and cooling systems, inspecting motors and wiring, and ensuring proper operation of key components. Daily maintenance should focus on cleaning, monitoring performance, and adjusting load..
Key tasks include changing oil and filters, cleaning air filters and cooling systems, inspecting motors and wiring, and ensuring proper operation of key components. Daily maintenance should focus on cleaning, monitoring performance, and adjusting load..
Mount a thermometer in the compressor room. Increase ventilation if room temperature exceeds operating limits. Inspect and remove/vacuum loose dust from inlet filters. Frequency depends on ambient dust load. Inspect and vacuum ambient side of coolers. Frequency depends on ambient dust load.
[pdf]